Product Details:
Payment & Shipping Terms:
|
Product: | Rotary Isolator Switch | Ampere: | 10A,16A,20A,25A,32A,40A,50A,63A,80A,100A |
---|---|---|---|
Poles: | 2pole, 3pole 4 Pole, 5pole | Red/Yellow Rings: | Lockable |
Color Of Handle: | Red / Black | IP Protection: | IP20 |
Highlight: | Rotary Cam Switch |
Semko Communication 5 Pole Rotary Isolator Switch DIN Rail , CE Rohs
KRIPAL HAS THE DESIGN PATENT FOR THIS SERIES SWITCHES.
Description:
Disconnect Switches from KRIPAL are hand-operated switchgear for main circuits with 90° switching angle and are offered as ON-OFF Switches (2, 3, 4, 6 and 8 pole) or as Changeover Switches with centre OFF (2, 3 and 4 pole).
Specifications:
No. |
Tech Parameters |
requirement |
1. |
Rated voltage |
below 440V |
2. |
rated current |
10A,16A,20A,25A,32A,40A,50A,63A,80A,100A |
3. |
frequency |
AC50HZ |
4. |
No. of poles |
2P,3P,4P,5P |
5. |
No. of layers |
make as required with circuit diagram |
6. |
panel size |
64*64mm |
7. |
color of handle |
Black/red |
8. |
Working temperature |
-25°C~+40°C |
9. |
Working height |
≤2,000m |
10. |
Relative humidity |
≤50% with highest temperature +40°C,but allow higher humidity with low temperature less than 40°C (eg.: humidity 90%----teperature20°C) |
11. |
Installation conditions |
pollution class III |
12. |
Mechanical life |
0.1*106times |
13. |
Electrical life |
0.03*106times |
14. |
Operative frequency |
120times/hour |
15. |
Transform angle |
90° |
Applications:
The switches must be selected according to the following performance specifications:
1) According to motor switching capacity, when the switch is fitted in such a way that the operator may use it for operational ON and OFF switching.
2) The rating data always applies to 3 poles. When the motor rating is divided between 6 poles, such as for star-delta switching, a 6 pole switch can be used to control 1.73 times
the rated power.
3) If the switch has a load-shedding Contact (LA), you can select the appropriate switch according to the uninterrupted current. The load-shedding contact is an auxiliary contact, which s closed in the ON position and opens early when witching off, so that a contactor located in the circuit takes over the switching duty and the maintenance/safety switch
operates at zero load. When switching on, the load-shedding contact closes later than or at the same time as the main contacts. With UKP and UKT switches this is the N/O auxiliary contact.
4)The "ON" position can be locked with a padlock (by altering the handle).
This is not permissible for switches with a red/yellow handle.
Features:
• Safety switches are always housed in insulated enclosures and have an inscription saying "Safety Switch" on a bright orange label.
• Switches to be used for emergency stop switching have a red handle and yellow locking collar in accordance with STOP category O (as per IEC/EN 60204/VDE 0113).
• If the switch is not approved for emergency stop switching, both parts will be black ("SW" part no. suffix).
• The cover and handle are interlocked by fitting a padlock.
Installation:
A. front mounting: four pole mounting; single hole mounting;
B. ase mounting: Snap-on mounting (DIN rail 35mm)
C. Enclosed Switches: PC enclosure; stainless steel enclosure
Optional:
a. Netural contacts
b. 1NO+1NC module
c. Color of handle and surroundings
With a broad range of mounting and operator options, KRIPAL Electric can provide economical, versatile and reliable solutions!
Contact Person: Mr. fov
Tel: 18810166789
Fax: 86-189-4289-0330
5 Years Warranty MN11-1 Mini Circuit Breaker With Soonest Delivery
6-32a Mini Circuit Breaker DPN Type MCB For Household Installation
Terminal 3P Mini Circuit Breaker For Pin / Fork Busbar Connection 6A 10A
22KA Moulded Case Residential Circuit Breaker , Miniature Circuit Breakers
Electrical Moulded Case Circuit Breakers Automotive , Commercial Circuit Breaker
MCCB Moulded Case 3 Pole Circuit Breakers Low Voltage , Industrial Circuit Breakers
Low Voltage 6A - 63A Residual Current Circuit Breaker With Compact Design
Residual Current Circuit Breaker With Own Design And Steady Market
Residual Current Circuit Breaker Low Voltage 6A - 63A With Compact Design