Product Details:
Payment & Shipping Terms:
|
Poles Available: | 2P, 4P | Ampere: | 16A 25A 40A 63A |
---|---|---|---|
Residual Protection: | Yes | Type: | Mini Circuit Breaker |
Leakage Current: | 10 30 100 300 500mA | Standard: | IEC1008 EN61008 |
Highlight: | Micro Circuit Breaker |
Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A
KRIPAL has the design patent for these items
A residual-current device (RCD), or residual-current circuit breaker (RCCB) is an electrical wiring device that disconnects a circuit whenever it detects that the electric current is not balanced between the energized conductor and the return neutral conductor. Such an imbalance may indicate current leakage through the body of a person who is grounded and accidentally touching the energized part of the circuit. A lethal shock can result from these conditions. RCCBs are designed to disconnect quickly enough to prevent injury caused by such shocks. They are not intended to provide protection against overcurrent (overload) or all short-circuit conditions.
Techinical data:
A. Conform to standard: GB16916.1
B. Rated voltage (Ue): 230V/400V; 50/60Hz
C. Rated current (A): 16, 25, 40, 63 A (2 poles and 4poles)
D. Rated leakage current: 10, 30, 100, 300, 500Ma
E. Electric life: ≥ 4000 times (on-off)
F. Mechanical life: ≥ 2000 times (on-off)
G. Case protection grade: IP40 after installing
Mechanical parameter
A. Installation mode: At the DIN rail of standard IEC
B. Terminal wiring capability: Conductor 1-25 mm
C. Width of shell: 2 poles 36mm; 4 poles 72 mm
Main characteristic
A. Various current specifications of leakage action ca easily ensure selective protection.
B. Inaccurate action resulting form the switch operation of electronic equipment can be avoided
C. Unless specified otherwise, the width of two-poles switch is two modules, four-poles(3P+N) is four modules
Specifications:
Technology Specification & Electrical Specification | |
Electric standard | IEC1008 EN61008 |
Trip time | Non-time delay; Minimal 10ms time delay |
Rated voltage | 230V/400V |
Rated surplus operating current | 10; 30; 100; 300mA, 500mA |
Selection grade | 3 |
Poles | 2pole 4pole |
Rated current | 16A, 25A, 40A, 63A |
Tripping character | B, C, D characteristic curve |
Terminal wiring | conductor 1-25 mm2 |
Environment capability | According to the IEC 1008 standard |
Case protection grade | IP40 after installation |
Electric life | Not less than 4000 times of breaking and closing |
Mechanical life | Not less than 2000 times of breaking and closing |
Mechanical Parameter | |
Installation mode | Installation at the DIN guide rail of 35mm |
Terminal block capacity | General thickness 0.8-2mm |
Main benefits:
High quality
Complete range
Instantaneous tripping current:
International Standard--- IEC 60898-1 and European Standard EN 60898-1 define the rated current In of a circuit breaker for low voltage distribution applications as the maximum current that the breaker is designed to carry continuously (at an ambient air temperature of 30 °C). The commonly-available preferred values for the rated current are 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A,[5] and 125 A (Renard series, slightly modified to include current limit of British BS 1363 sockets). The circuit breaker is labeled with the rated current in amperes, but without the unit symbol "A". Instead, the ampere figure is preceded by a letter "B", "C" or "D", which indicates the instantaneous tripping current — that is, the minimum value of current that causes the circuit breaker to trip without intentional time delay (i.e., in less than 100 ms), expressed in terms of In:
Type |
Instantaneous tripping current |
B |
above 3 In up to and including 5 In |
C |
above 5 In up to and including 10 In |
D |
above 10 In up to and including 20 In |
Contact Person: Mr. fov
Tel: 18810166789
Fax: 86-189-4289-0330
5 Years Warranty MN11-1 Mini Circuit Breaker With Soonest Delivery
6-32a Mini Circuit Breaker DPN Type MCB For Household Installation
Terminal 3P Mini Circuit Breaker For Pin / Fork Busbar Connection 6A 10A
22KA Moulded Case Residential Circuit Breaker , Miniature Circuit Breakers
Electrical Moulded Case Circuit Breakers Automotive , Commercial Circuit Breaker
MCCB Moulded Case 3 Pole Circuit Breakers Low Voltage , Industrial Circuit Breakers
Low Voltage 6A - 63A Residual Current Circuit Breaker With Compact Design
Residual Current Circuit Breaker With Own Design And Steady Market